|
Bio-Techne corporation
human il-6 antibody Human Il 6 Antibody, supplied by Bio-Techne corporation, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/human+il/custom%40af-206-na%4010%2E1016%2Fj%2Eisci%2E2026%2E116766?v=Bio-Techne+corporation Average 94 stars, based on 1 article reviews
human il-6 antibody - by Bioz Stars,
2026-08
94/100 stars
|
Buy from Supplier |
|
Miltenyi Biotec
il7 Il7, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/human+il/us12698315-687-29-30?v=Miltenyi+Biotec Average 93 stars, based on 1 article reviews
il7 - by Bioz Stars,
2026-08
93/100 stars
|
Buy from Supplier |
|
MedChemExpress
il-1 alpha, human Il 1 Alpha, Human, supplied by MedChemExpress, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/human+il/custom%40hy-p7027%4042537705?v=MedChemExpress Average 93 stars, based on 1 article reviews
il-1 alpha, human - by Bioz Stars,
2026-08
93/100 stars
|
Buy from Supplier |
|
Multi Sciences (Lianke) Biotech Co Ltd
human il-1ra/il-1f3 elisa kit Human Il 1ra/Il 1f3 Elisa Kit, supplied by Multi Sciences (Lianke) Biotech Co Ltd, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/human+il/custom%40ek1132%4042485758?v=Multi+Sciences+%28Lianke%29+Biotech+Co+Ltd Average 94 stars, based on 1 article reviews
human il-1ra/il-1f3 elisa kit - by Bioz Stars,
2026-08
94/100 stars
|
Buy from Supplier |
|
R&D Systems
il 8 ![]() Il 8, supplied by R&D Systems, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/human+il/pmc13054578-81-31-33?v=R%26D+Systems Average 96 stars, based on 1 article reviews
il 8 - by Bioz Stars,
2026-08
96/100 stars
|
Buy from Supplier |
|
Thermo Fisher
interleukin 4 il 4 ![]() Interleukin 4 Il 4, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/human+il/pmc13091955-314-0-30?v=Thermo+Fisher Average 94 stars, based on 1 article reviews
interleukin 4 il 4 - by Bioz Stars,
2026-08
94/100 stars
|
Buy from Supplier |
|
R&D Systems
il 10 duoset elisa ![]() Il 10 Duoset Elisa, supplied by R&D Systems, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/human+il/pmc13050104-62-5-8?v=R%26D+Systems Average 96 stars, based on 1 article reviews
il 10 duoset elisa - by Bioz Stars,
2026-08
96/100 stars
|
Buy from Supplier |
|
R&D Systems
human il ![]() Human Il, supplied by R&D Systems, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/human+il/pmc13050104-62-0-8?v=R%26D+Systems Average 96 stars, based on 1 article reviews
human il - by Bioz Stars,
2026-08
96/100 stars
|
Buy from Supplier |
|
Bio-Techne corporation
human il-33 quantikine elisa kit ![]() Human Il 33 Quantikine Elisa Kit, supplied by Bio-Techne corporation, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/human+il/custom%40d3300b%4042314770?v=Bio-Techne+corporation Average 94 stars, based on 1 article reviews
human il-33 quantikine elisa kit - by Bioz Stars,
2026-08
94/100 stars
|
Buy from Supplier |
|
Miltenyi Biotec
recombinant human il 21 miltenyi biotec ![]() Recombinant Human Il 21 Miltenyi Biotec, supplied by Miltenyi Biotec, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/human+il/pm42486103-554-23-26?v=Miltenyi+Biotec Average 94 stars, based on 1 article reviews
recombinant human il 21 miltenyi biotec - by Bioz Stars,
2026-08
94/100 stars
|
Buy from Supplier |
Journal: Military Medical Research
Article Title: The cellular response capacity (CRC) as a novel immunomonitoring approach in sepsis
doi: 10.1016/j.mmr.2026.100010
Figure Lengend Snippet: Concentration-dependent change in the humoral inflammatory response following incubation with Escherichia coli ( E. coli ) in the ex vivo whole blood model. a Absolute plasma concentrations of IL-6, IL-8, and MMP9 determined by enzyme-linked immunosorbent assay. b Normalized values and EC 50 curve fit by BuC=0% and 50 000 CFU/ml E. coli= 100%, respectively, for IL-6, IL-8, and MMP9 as indicated by EC 50 (%) on the respective Y-axis. BuC indicates buffer control after 60 min incubation; numbers on the X-axis indicate E. coli bacteria in concentrations of 2000 to 50 000 CFU/ml after 60 min incubation; LPS indicates lipopolysaccharide (LPS) 100 ng/ml after 60 min incubation. Values are shown as median and interquartile range. n =8. Statistical analysis was performed using the Kruskal-Wallis test with Dunn’s post-hoc test, comparing all shown concentrations of E. coli bacteria and 100 ng/ml LPS with BuC. P -values are indicated above the respective data points. ⁎ P <0.05, ⁎⁎ P <0.01, ⁎⁎⁎ P <0.001. CFU. Colony-forming units; IL. Interleukin; MMP9. Matrix metallopeptidase 9.
Article Snippet: For the samples of the ex vivo whole blood model, the plasma concentrations of matrix metallopeptidase 9 (MMP9, #DY911, R&D Systems, Minneapolis, USA), IL-6 (#555220, BD Biosciences, San Jose, USA), and
Techniques: Concentration Assay, Incubation, Ex Vivo, Clinical Proteomics, Enzyme-linked Immunosorbent Assay, Control, Bacteria
Journal: Military Medical Research
Article Title: The cellular response capacity (CRC) as a novel immunomonitoring approach in sepsis
doi: 10.1016/j.mmr.2026.100010
Figure Lengend Snippet: Diagnostic performance for the detection of bacteremia, analyzing the neutrophil phenotype by determining the median fluorescence intensity (MFI) and the cellular response capacity (CRC) in comparison with traditional markers of humoral inflammation (IL-6, IL-8, MMP9). a Comparison of receiver operating characteristic (ROC) at 10,000 CFU/ml Escherichia coli ( E. coli ) with the respective 95% confidence interval (CI) and P -value, and half-maximal effective concentration (EC 50 ) as a function of the E. coli concentration. b Detailed comparison of the EC 50 as a function of the E. coli concentration. c Exemplary comparison of EC 50 curve fit after normalization as indicated by EC 50 (%) on the respective Y-axis to BuC=100% and 50 000 CFU/ml E. coli =0% for the humoral marker IL-6 (the IL-6 values were multiplied by −1 before EC 50 calculation to facilitate comparability with the CRC) and the change in neutrophil phenotype represented by CD11b CRC. BuC indicates buffer control after 60 min incubation; numbers on the X-axis of c indicate E. coli bacteria in concentrations of 2000 to 50 000 CFU/ml after 60 min incubation. Values are shown as median and interquartile range. n =8. Statistical analysis was performed using the Kruskal-Wallis test with Dunn’s post-hoc test, evaluating the EC 50 of IL-8, MMP9, the MFI, and CRC of CD10, CD11b, and CD62L in comparison to the EC 50 of IL-6. P -values are indicated above the respective data points. ⁎ P <0.05. CFU. Colony-forming units; IL. Interleukin; MMP9. Matrix metallopeptidase 9.
Article Snippet: For the samples of the ex vivo whole blood model, the plasma concentrations of matrix metallopeptidase 9 (MMP9, #DY911, R&D Systems, Minneapolis, USA), IL-6 (#555220, BD Biosciences, San Jose, USA), and
Techniques: Diagnostic Assay, Fluorescence, Comparison, Concentration Assay, Marker, Control, Incubation, Bacteria
Journal: Military Medical Research
Article Title: The cellular response capacity (CRC) as a novel immunomonitoring approach in sepsis
doi: 10.1016/j.mmr.2026.100010
Figure Lengend Snippet: Clinical specifications and parameters over all time points of the sepsis cohort. a Suspected infection cause of sepsis. b Distribution of the individual score points of the Sequential Organ Failure Assessment (SOFA) score. c Total SOFA score. d-h Traditional and humoral markers of inflammation: leukocytes and neutrophil-lymphocyte ratio ( d ), C-reactive protein (CRP) and procalcitonin (PCT) ( e ), interleukin-6 (IL-6) and interleukin-8 (IL-8) ( f ), serum amyloid A (SAA) and calprotectin ( g ), matrix metallopeptidase 9 (MMP9) and myeloperoxidase (MPO) ( h ). Values are shown as median and interquartile range. n =14. CNS. Central nervous system; HV. Healthy volunteers.
Article Snippet: For the samples of the ex vivo whole blood model, the plasma concentrations of matrix metallopeptidase 9 (MMP9, #DY911, R&D Systems, Minneapolis, USA), IL-6 (#555220, BD Biosciences, San Jose, USA), and
Techniques: Infection
Journal: Non-coding RNA Research
Article Title: CircSMAD4 shapes matrix-remodeling TAMs in lung adenocarcinoma
doi: 10.1016/j.ncrna.2026.03.003
Figure Lengend Snippet: circSMAD4 drives tumor-educated M2-like polarization of macrophages and promotes tumor-cell aggressiveness. (A) Workflow for generating TC-hMDMs and TC-BMDMs, circSMAD4 knockdown, and downstream functional assays. (B) RT–qPCR analysis of M1-associated markers (MHC-II [HLA-DRA in TC-hMDMs; H2-Ab1 in TC-BMDMs], NOS2, and CD86) and M2-associated markers (CD163, CD206, and ARG1) in TC-hMDMs and TC-BMDMs. (C) Representative flow-cytometry histograms for HLA-DR, iNOS, CD86, CD163, CD206, and ARG1 in TC-hMDMs. Gating strategy and marker thresholds were defined based on FMO controls (see ). (D) Flow-cytometry quantification of marker-positive cells in TC-hMDMs and TC-BMDMs. (E) ELISA of IL-10, TGF-β, and iNOS in culture supernatants. (F) CCK-8 assays of A549 and LLC cells. (G) Colony-formation assays of A549 and LLC cells with quantification. (H) Bioluminescence-based growth readouts of patient-derived LUAD organoids (PDO #1 and PDO #2) after co-culture with TC-hMDMs. (I) Immunoblot analysis of EMT-related proteins (E-cadherin, N-cadherin, Vimentin) in A549 and LLC cells. (J) Transwell migration and invasion assays of A549 and LLC cells with quantification. Scale bar, 50 μm. ∗P < 0.05; ∗∗P < 0.01; ∗∗∗P < 0.001; ∗∗∗∗P < 0.0001; ns, not significant.
Article Snippet: Human IL-10 was quantified using
Techniques: Knockdown, Functional Assay, Quantitative RT-PCR, Flow Cytometry, Marker, Enzyme-linked Immunosorbent Assay, CCK-8 Assay, Derivative Assay, Co-Culture Assay, Western Blot, Migration
Journal: Non-coding RNA Research
Article Title: CircSMAD4 shapes matrix-remodeling TAMs in lung adenocarcinoma
doi: 10.1016/j.ncrna.2026.03.003
Figure Lengend Snippet: circSMAD4 drives tumor-educated M2-like polarization of macrophages and promotes tumor-cell aggressiveness. (A) Workflow for generating TC-hMDMs and TC-BMDMs, circSMAD4 knockdown, and downstream functional assays. (B) RT–qPCR analysis of M1-associated markers (MHC-II [HLA-DRA in TC-hMDMs; H2-Ab1 in TC-BMDMs], NOS2, and CD86) and M2-associated markers (CD163, CD206, and ARG1) in TC-hMDMs and TC-BMDMs. (C) Representative flow-cytometry histograms for HLA-DR, iNOS, CD86, CD163, CD206, and ARG1 in TC-hMDMs. Gating strategy and marker thresholds were defined based on FMO controls (see ). (D) Flow-cytometry quantification of marker-positive cells in TC-hMDMs and TC-BMDMs. (E) ELISA of IL-10, TGF-β, and iNOS in culture supernatants. (F) CCK-8 assays of A549 and LLC cells. (G) Colony-formation assays of A549 and LLC cells with quantification. (H) Bioluminescence-based growth readouts of patient-derived LUAD organoids (PDO #1 and PDO #2) after co-culture with TC-hMDMs. (I) Immunoblot analysis of EMT-related proteins (E-cadherin, N-cadherin, Vimentin) in A549 and LLC cells. (J) Transwell migration and invasion assays of A549 and LLC cells with quantification. Scale bar, 50 μm. ∗P < 0.05; ∗∗P < 0.01; ∗∗∗P < 0.001; ∗∗∗∗P < 0.0001; ns, not significant.
Article Snippet:
Techniques: Knockdown, Functional Assay, Quantitative RT-PCR, Flow Cytometry, Marker, Enzyme-linked Immunosorbent Assay, CCK-8 Assay, Derivative Assay, Co-Culture Assay, Western Blot, Migration